integration:ros
Dies ist eine alte Version des Dokuments!
ROS measurement system integration
The ROS-integration is based on rosjava. Connections to one or more running ROS systems are possible. The master uri of a ros system has to be configured as property of the measurement system configuration as follow:
<?xml version="1.0" encoding="iso-8859-1" ?> <MeasurementProcess name="Upperlimb Measurement"> <MeasurementSystem id="default" system="ROS" fileSuffix="r3d"> <Property name="localhost" value="192.168.10.100"/> <Property name="masteruri" value="http://192.168.10.2:11311"/> <TransducerUnitGroup name="vicon/RightHumerus" displayName="RightHumerus"> <TransducerUnit name="RightHumerus" displayName="RightHumerus" sampleRate="120"> ... ... ... </MeasurementProcess>
Property name | Description | Optional |
---|---|---|
masteruri | The ip of the ROS master. | No |
localhost | The ip of the networkinterface used to connecto to the ROS master. Without using it, a default value is determined automatically which can result in the wrong ip, if more than one network adapters are available. | Yes |
integration/ros.1580887615.txt.gz · Zuletzt geändert: 2020/02/05 08:26 von oliver