Benutzer-Werkzeuge

Webseiten-Werkzeuge


processconfiguration

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen RevisionVorhergehende Überarbeitung
Nächste Überarbeitung
Vorhergehende Überarbeitung
Nächste ÜberarbeitungBeide Seiten der Revision
processconfiguration [2020/07/21 11:30] – [Configuration of the trial types] oliverprocessconfiguration [2020/12/11 09:18] – [Additionel export of subsets of the data] oliver
Zeile 100: Zeile 100:
 ^ duration | seconds | float | The duration of the recording. If not set variable-length-recording should be used. But this is currently not implemented. | No | ^ duration | seconds | float | The duration of the recording. If not set variable-length-recording should be used. But this is currently not implemented. | No |
 ^ offset | seconds | float | An offset/time interval to wait after start triggering bevor starting the recording | Yes | ^ offset | seconds | float | An offset/time interval to wait after start triggering bevor starting the recording | Yes |
-^ closeOffset | seconds | float | An offset/time interval to wait after recording and before closing the robotUseful to wait that a robot move back to a default start position. | Yes |+^ closeOffset | seconds | float | An offset/time interval to wait after recording and before closing the recording.This can be useful if a sequence of trials is recorded and after the last trial the trigger has to wait before a closing procedure is executed, e.g. a robot needs time to move to a start position before the robot program is closed. | Yes |
 ^ measurementSystemConfigIds | | String | A list of measurement system IDs to be used. All measurementsystem which are not listed here are automatically disabled. | No | ^ measurementSystemConfigIds | | String | A list of measurement system IDs to be used. All measurementsystem which are not listed here are automatically disabled. | No |
 ^ labelset | | String | The name of the labelset to define, which data should be written into files. Details are described in the chapter "Configuration of the output" (filename with suffix xml).| Yes | ^ labelset | | String | The name of the labelset to define, which data should be written into files. Details are described in the chapter "Configuration of the output" (filename with suffix xml).| Yes |
Zeile 118: Zeile 118:
 ^ Attribute name ^ Description | ^ Attribute name ^ Description |
 ^ cyclesSequence | A space separated list of trial type names | ^ cyclesSequence | A space separated list of trial type names |
 +^ pressButtonForNextCycle | if set to "true" between switching to an other trial type a dialog box is opended and a butto must be pressed. This cancel option allows to cancel the complete measurement process. |
 ====Trigger configuration==== ====Trigger configuration====
 =====Configuration of the output===== =====Configuration of the output=====
Zeile 201: Zeile 202:
 ^ Mimetype ^ Description ^ ^ Mimetype ^ Description ^
 ^ text/x-csv | A CSV-file with timeseries. The delimiter can be configured in the Options-Pane. A header is given. No metadata are saved. | ^ text/x-csv | A CSV-file with timeseries. The delimiter can be configured in the Options-Pane. A header is given. No metadata are saved. |
 +
 +====Output files for multiple measurement systems====
 +If more than one measurementsystem is used, for each a separate labelgroup has to be defined in the labelset. Each labelgroup must define the property "fileSuffix" with the system name of the measurement system as its value. The value is identical to the value of the "name"-attribute of the labelgroup. It is not used as a real file suffix. The file suffix is overwritten by the configuration in the in the measuremetsystem configuration.
 ==== Metadata==== ==== Metadata====
  
processconfiguration.txt · Zuletzt geändert: 2021/01/25 11:42 von oliver

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki