integration:vicon [2020/09/16 10:57] oliverintegration:vicon [2022/01/27 19:54] (aktuell) oliver
Zeile 1: Zeile 1:
 =====Vicon measurement system integration===== =====Vicon measurement system integration=====
 The Vicon-integration is based on [[https://github.com/MobMonRob/JViconDataStream2|JDataAquisition]], a java library wrapper of Vicons [[https://www.vicon.com/software/datastream-sdk/|DataStream SDK]]. Connections to one or more running Vicon systems are possible.  The Vicon-integration is based on [[https://github.com/MobMonRob/JViconDataStream2|JDataAquisition]], a java library wrapper of Vicons [[https://www.vicon.com/software/datastream-sdk/|DataStream SDK]]. Connections to one or more running Vicon systems are possible. 
 +
 +The value of the attribute "system" from the element <MeasurementSystem> has to be set to "Vicon".
 +
 +**Example configuration fragment:**
 +
 +<code xml>
 +<?xml version="1.0" encoding="UTF-8"?>
 +
 +<MeasurementProcess name="Test Vicon measurement system integration">
 +
 + <MeasurementSystem id="default" system="Vicon" fileSuffix="v3d">
 +        <Property name="sampleRate" value="120.0"/>
 +        <Property name="dnsidentifiablename" value="192.168.10.1"/>
 +        <!--Property name="timeout" value="10000"/-->
 +
 +        <TransducerUnitGroup name="TCP" displayName="TCP">   
 +            <TransducerUnit name="TCP" displayName="TCP">
 +                <Channel name="q0"/>
 +                <Channel name="q1"/>
 +                <Channel name="q2"/>
 +                <Channel name="q3"/>
 +                <Channel name="v0"/>
 +                <Channel name="v1"/>
 +                <Channel name="v2"/>
 +            </TransducerUnit>
 +        </TransducerUnitGroup>
 +        ...
 +        <TransducerUnitGroup name="markers" displayName="Markers">   
 +            
 +            <TransducerUnit name="GLOBE1" displayName="GLOBE1">
 +                <Channel name="v0"/>
 +                <Channel name="v1"/>
 +                <Channel name="v2"/>
 +                <Channel name="T"/>
 +            </TransducerUnit>
 +            ...
 +        </TransducerUnitGroup>
 + </MeasurementSystem>   
 + ...
 +</MeasurementProcess>
 +</code>
 +
 +**The <MeasurementSystem>-element has the following additional properties:**
 +
 +^ Property name ^ Description ^ Optional |
 +^ dnsidentifiablename | A name possibly resolveable by the DNS | No |
 +^ bufferSize | The size of the receiving data buffer. Default value is 1 | Yes |
 +^ isMarkerDataEnabled | Should labeled marker data be transmitted and avaiable to be saved. | Yes |
 +^ isMarkerRayDataEnabled | Should marker ray data be transmitted and avaiable to be saved. | Yes |
 +^ isDeviceDataEnabled | Should device data be transmitted and avaiable to be saved. | Yes |
 +^ isUnlabeledMarkerDataEnabled | Should unabled marker data be transmitted and avaiable to be saved. | Yes |
 +^ isSegmentDataEnabled | Should segment data be transmitted and avaiable to be saved. | Yes |
 +^ isLightweightSegmentDataEnabled | Should segment data be transmitted and avaiable to be saved. | Yes |
 +^ isVideoDataEnabled | Should video data be transmitted and avaiable to be saved. | Yes |
 +^ isCentroidDataEnabled | Should centroid data be transmitted and available to be saved. | Yes |
 +^ isGreyscaleDataEnabled | Should greyscaledata be transmitted and available to be saved. | Yes |
 +^ streamingMode | ClientPull or ClientPullPreFetch or ServerPush | Yes |
 +
 +Keep in mind: The first frame got by the ViconDataStream is always 0. This seems to be a bug in the Vicon DataStream API.
 +
 +The channel names are fix for the markers and segments but are configurable in principle for devices. TransducerUnitGroups with the names listed in the following table have a specific meaning. All other names are interpreted as subject names corresponding to the names configured in Vicon Tracker/Nexus. 
 +
 +^ tranducer unit group name ^ Description ^
 +^ markers | This group contains units corresponding to markers | 
 +^ devices | This group contains units corresponding to devices | 
 +
 +Marker unit can have channels with the names shown in the following table:
 +
 +^ channel name ^ Description ^
 +^ v0 | x coordinate of the position of the marker | 
 +^ v1 | y coordinate of the position of the marker |
 +^ v2 | z coordinate of the position of the marker |
 +^ T | timestamp corresponding to the marker. |
 +^ q | quality of the tracking of the marker |
 +
 +Segment units can have channels with the names shown in the following table:
 +
 +^ channel name ^ Description ^
 +^ v0 | x coordinate of the position of the marker | 
 +^ v1 | y coordinate of the position of the marker |
 +^ v2 | z coordinate of the position of the marker |
 +^ q0 ||
 +^ q1 ||
 +^ q2 ||
 +^ q3 ||
 +^ T | timestamp corresponding to the marker. |
 +^ q | quality of the tracking of the marker |
 +
 +