start
Unterschiede
Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen RevisionVorhergehende ÜberarbeitungNächste Überarbeitung | Vorhergehende ÜberarbeitungLetzte ÜberarbeitungBeide Seiten der Revision | ||
start [2021/08/31 11:08] – [Unreleased] oliver | start [2023/02/08 12:52] – [Unreleased] oliver | ||
---|---|---|---|
Zeile 9: | Zeile 9: | ||
=== Unreleased === | === Unreleased === | ||
+ | |||
+ | ---- | ||
+ | == JDAQ 0.40 - 2023-02 == | ||
+ | ---- | ||
+ | |||
+ | **Added** | ||
+ | * new Properties " | ||
+ | ---- | ||
+ | == JDAQ 0.39 - 2022-07 == | ||
+ | ---- | ||
+ | |||
+ | **Added** | ||
+ | * Added Mediapipe ROS topic | ||
+ | |||
+ | ---- | ||
+ | == JDAQ 0.38 - 2021-09 == | ||
+ | ---- | ||
+ | |||
+ | **Added** | ||
+ | * Added properties to configure centroid-data, | ||
+ | * Added property " | ||
+ | * Recording properties from Vicon (process Rate, latency information and count of lost frames) are saved into the recorded trial. | ||
+ | |||
+ | **Fixed** | ||
+ | * Several bugs fix in MeasurementSystem.record(): | ||
+ | * Wrong precondition for invocation of setStreamMode() | ||
+ | |||
+ | **TODO** | ||
+ | * Handling of unlabled markers for the Vicon system | ||
+ | * Moving unit/group properties which are currently shown at the plane of the measurement system | ||
---- | ---- | ||
Zeile 17: | Zeile 47: | ||
* Closing the RPS-Software disconnectes the socket connection but does not automatically reconnects the session after restarting the RPS. In consequence JDAQ can not collect data any more and must be restarted. This problem is solved by checking the connection always before recording starts to subscribe to the socket if needed. If the socket is closed a warning is written to the output and the corresponding connection-property is updated so that the disconnection status is shown in the properties ui. | * Closing the RPS-Software disconnectes the socket connection but does not automatically reconnects the session after restarting the RPS. In consequence JDAQ can not collect data any more and must be restarted. This problem is solved by checking the connection always before recording starts to subscribe to the socket if needed. If the socket is closed a warning is written to the output and the corresponding connection-property is updated so that the disconnection status is shown in the properties ui. | ||
- | * If the ROS HOST IP enviroment variable on the ROS host is not set then it can happen that resvoling | + | * If the ROS_IP |
---- | ---- | ||
== JDAQ 0.36 - 2021-03 == | == JDAQ 0.36 - 2021-03 == |